Quick List

Outdoor Weather Warning Sirens

The City of Newnan has eight outdoor weather warning sirens placed in the following locations:   

  1. Berry Avenue
  2. Bullsboro Drive
  3. Perry Street
  4. Sprayberry Road
  5. Mary Freeman Road
  6. Lower Fayetteville Road
  7. VC Street
  8. Waterworks Road

  

  

  

 

 

 

 





 

 

 

In 2009, Coweta County 911, Coweta County Emergency Management and Newnan Utilities entered into a Memorandum of Understanding to establish the roles and responsibilities of each party during the use of the weather sirens during a tornado warning declared by the National Weather Service. The weather sirens will be used to support the warning efforts of the citizens of Newnan, Georgia. 

It is understood that Coweta County 911 will:

a. Notify Newnan Utilities Control Room and advise them that Newnan/Coweta County has been placed under a tornado warning by the National Weather Service.

It is understood that Coweta County Emergency Management will:

a. Request that Newnan Utilities activate the weather sirens in the event that the City of Newnan is included in the tornado warning by the National Weather Service.

It is understood that Newnan Utilities will:

a. At the request of Coweta County Emergency Management activate the weather sirens.

b. Activate the weather sirens at their discretion.

The outdoor weather warning sirens are intended to alert people that are outdoors to seek shelter due to hazardous weather conditions. While the sirens can sometimes be heard inside structures, the sound volume can be diminished by the distance, topography, and other variables. Televisions, weather radios or the use of the internet are also beneficial resources for severe weather notifications while inside a structure.

Monthly Testing: 

Monthly testing of the sirens is performed at 11am on the first Wednesday of each month by Newnan Utilities. If a weather event is occurring during the normal test time, the tests are rescheduled for the following Wednesday at 11am. 

 
carnegie.JPG

Report Issues

Other Links

Camera Ready Logo
SPLOST.png
 
Building Department PDF Print E-mail
Monday, 02 April 2007
Image
Bill Stephenson

The Building Department provides for administration and enforcement of building, housing, plumbing, electrical, health and zoning codes as adopted by the Newnan City Council. For new construction and alterations to existing facilities, the department issues the necessary permits, examines all plans and checks for compliance with building and zoning codes. This department also inspects properties for code compliance routinely and as requested. The goal of the Building Department is to protect the lives and welfare of our citizens by allowing and maintaining only the highest quality standards.

The Current State Minimum Standard Codes
The following are the current state minimum standard codes for construction as adopted by the Board of Community Affairs.

Current Codes as Adopted by DCA - Mandatory Codes
• ICC International Building Code 2006 Edition
• ICC International Gas Code 2006 Edition
• ICC International Mechanical 2006 Edition
• ICC International Plumbing 2006 Edition
• National Electrical Code, 2008 Edition
• ICC International Fire Prevention Code 2006 Edition
• International Energy Conservation Code, 2006 Edition
• ICC International Residential Code 2006 Edition

PLEASE NOTE: There are Georgia Amendments to most of the following codes. Please contact the Construction Codes and Industrialized Buildings Section for more information concerning these amendments.

 

Permit Applications must include at a minimum
• Site plan
• Building plan
• Manual J or Comchek or other report showing energy compliance
• Contractors license or affidavit
• Applicable fees

Building Department Documents and Forms


Plan Submittals

DRAWINGS AND SPECIFICATIONS

REQUIREMENTS - Two or more copies of specifications and of drawings drawn to scale with sufficient clarity and detail to indicate the nature and character of the work, shall accompany the application for a permit. Such drawings and specifications shall contain information, in the form of notes or otherwise, as to the quality of materials, where quality is essential to conformity with the construction codes. Such information shall be specific, and the construction codes shall not be cited as a whole or in part, nor shall the term “legal” or its equivalent be used, as a substitute for specific information. All information, drawings, specifications and accompanying data shall bear the name and signature of the person responsible for the design. Copies of drawings and specifications will not be accepted with the permit application unless specifically authorized by the design professional

DESIGN PROFESSIONAL - The design professional shall be an architect or engineer legally registered under the laws of this state regulating the practice of architecture or engineering and shall affix his official seal to said drawings, specifications and accompanying data, for the following:

1. All Group A, E, and I occupancies.
2. Buildings or Structures three stories or more high.
3. Buildings and structures 5,000 sq. ft. or more in area.

For all other buildings and structures, the submittal shall bear the certification of the applicant that some specific state law exception permits its preparation by a person not so registered.

EXCEPTION - Single-family dwellings (R-3 occupancy), regardless of size, shall require neither a registered architect nor engineer.

TITLE PAGE - The cover page of the architectural plans must include all necessary and critical data for completing a thorough plan review. This page must include all owners’ information, all contractors’ information, and all project information. The project information must include:
1. Scope (description) of work.
2. All applicable construction code editions.
3. Construction Type, Use, and Occupancy Classification.
4. Square footage of each floor and basement areas.
5. Number of floors.
6. Allowable occupant load and required number of exits.
7. Zoning classification.
8. Indicate whether building is sprinklered or non-sprinklered.
9. Original stamp, date and signature from the design professional.
10. Page index.

 

Bill Stephenson
Building Official
25 LaGrange Street
Newnan, GA 30263
Email Me
Phone: 770-254-2362
Fax: 770-254-2353